Back to Top

Hi, Guest!
  • FLUKE
  • Fluke 572-2 High-Temperature Infrared Thermometer 081908101888

Fluke 572-2 High-Temperature Infrared Thermometer 081908101888

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
15 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Fluke 572-2 High-Temperature Infrared Thermometer 081908101888

Fluke 572-2 High-Temperature Infrared Thermometer 081908101888 Infrared Measurements Infrared temperature range -30 ° C to 900 ° C ( -22 ° F to 1652 ° F) IR accuracy ( calibration geometry with ambient temperature 23 ° C ± 2 ° C) e 0° C: ± 1° C or ± 1 % of the reading, whichever is greater e-10 ° C to < 0 ° C: ± 2° C < -10° C: ± 3 ° C e32° F: ± 2° F or ± 1% of the reading, whichever is greater e14 ° F to < 32 ° F: ± 4 ° F < 14 ° F: ± 6 ° F IR repeatability ± 0.5 % of reading or ± 0.5 ° C ( ± 1 ° F) , whichever is greater Display resolution 0.1 ° C / 0.1 ° F Distance: Spot 60: 1 ( calculated at 90 % energy) Minimum spot size 19 mm Laser sighting Offset dual laser, output < 1 mW Spectral response 8 ¼ m to 14 ¼ m Response time ( 95 % ) < 500 ms Emissivity Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials Contact Measurements K-type thermocouple input temperature range -270 ° C to 1372 ° C ( -454 ° F to 2501 ° F) K-type thermocouple input accuracy ( with ambient temperature 23 ° C ± 2 ° C) < -40 ° C: ± ( 1 ° C + 0.2 ° / 1 ° C) e-40 ° C: ± 1 % or 1 ° C, whichever is greater < -40 ° F: ± ( 2 ° F + 0.2 ° / 1 ° F) e-40 ° F: ± 1 % or 2 ° F, whichever is greater K-type thermocouple 0.1 ° C/ 0.1 ° F K-type thermocouple repeatability ± 0.5 % of reading or ± 0.5 ° C ( ± 1 ° F) , whichever is greater Measurement Options Hi/ Low alarms Audible and two-color visual Min/ Max/ Avg/ Dif Yes Switchable celsius and fahrenheit Yes Backlight Two levels, normal and extra bright for darker environments Probe input K-type thermocouple simultaneous display of probe and IR temperature Trigger lock Yes Data storage 99 points Display Dot matrix 98 x 96 pixels with function menus Communication USB 2.0 K-Type Thermocouple Specifications Measurement range ( bead probe) -40 ° C to 260 ° C ( -40 ° F to 500 ° F) Accuracy ± 1.1 ° C ( ± 2.0 ° F) from 0 ° C to 260 ° C ( 32 ° F to 500 ° F) . Typically within 1.1 ° C ( 2.0 ° F) from -40 ° C to 0 ° C ( -40 ° F to 32 ° F) Cable length 1 m ( 40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination General Specifications Safety and compliance IEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009 Operating temperature 0 ° C to 50 ° C ( 32 ° F to 122 ° F) Storage temperature -20 ° C to 60 ° C ( -4 ° F to 140 ° F) Relative humidity 10 % to 90 % RH non-condensing up to 30 ° C ( 86 ° F) Operating altitude 2000 meters above mean sea level Weight 0.322 kg ( 0.7099 lb) Power 2 AA batteries Battery life 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle ( thermometer continuously on) Hubungi PUTRA BUANA INSTRUMENT Telp : 02151176451 fax : 021-7302811 CP : irfan 081908101888 email : irfan.syihabudin@ gmail.com web : http: / / www.buanasurvey.net
Tampilkan Lebih Banyak