Detail Fluke 572-2 High-Temperature Infrared Thermometer 081908101888
Fluke 572-2 High-Temperature Infrared Thermometer 081908101888
Infrared Measurements
Infrared temperature range -30 ° C to 900 ° C ( -22 ° F to 1652 ° F)
IR accuracy ( calibration geometry with ambient temperature 23 ° C ± 2 ° C) e 0° C: ± 1° C or ± 1 % of the reading, whichever is greater
e-10 ° C to < 0 ° C: ± 2° C
< -10° C: ± 3 ° C
e32° F: ± 2° F or ± 1% of the reading, whichever is greater
e14 ° F to < 32 ° F: ± 4 ° F
< 14 ° F: ± 6 ° F
IR repeatability ± 0.5 % of reading or ± 0.5 ° C ( ± 1 ° F) , whichever is greater
Display resolution 0.1 ° C / 0.1 ° F
Distance: Spot 60: 1 ( calculated at 90 % energy)
Minimum spot size 19 mm
Laser sighting Offset dual laser, output < 1 mW
Spectral response 8 ¼ m to 14 ¼ m
Response time ( 95 % ) < 500 ms
Emissivity Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
Contact Measurements
K-type thermocouple input temperature range -270 ° C to 1372 ° C ( -454 ° F to 2501 ° F)
K-type thermocouple input accuracy ( with ambient temperature 23 ° C ± 2 ° C) < -40 ° C: ± ( 1 ° C + 0.2 ° / 1 ° C)
e-40 ° C: ± 1 % or 1 ° C, whichever is greater
< -40 ° F: ± ( 2 ° F + 0.2 ° / 1 ° F)
e-40 ° F: ± 1 % or 2 ° F, whichever is greater
K-type thermocouple 0.1 ° C/ 0.1 ° F
K-type thermocouple repeatability ± 0.5 % of reading or ± 0.5 ° C ( ± 1 ° F) , whichever is greater
Measurement Options
Hi/ Low alarms Audible and two-color visual
Min/ Max/ Avg/ Dif Yes
Switchable celsius and fahrenheit Yes
Backlight Two levels, normal and extra bright for darker environments
Probe input K-type thermocouple simultaneous display of probe and IR temperature
Trigger lock Yes
Data storage 99 points
Display Dot matrix 98 x 96 pixels with function menus
Communication USB 2.0
K-Type Thermocouple Specifications
Measurement range ( bead probe) -40 ° C to 260 ° C ( -40 ° F to 500 ° F)
Accuracy ± 1.1 ° C ( ± 2.0 ° F) from 0 ° C to 260 ° C ( 32 ° F to 500 ° F) . Typically within 1.1 ° C ( 2.0 ° F) from -40 ° C to 0 ° C ( -40 ° F to 32 ° F)
Cable length 1 m ( 40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
General Specifications
Safety and compliance IEC 60825-1
FDA Laser Class II
IEC 61326-1
CE Complaint
CMC # 01120009
Operating temperature 0 ° C to 50 ° C ( 32 ° F to 122 ° F)
Storage temperature -20 ° C to 60 ° C ( -4 ° F to 140 ° F)
Relative humidity 10 % to 90 % RH non-condensing up to 30 ° C ( 86 ° F)
Operating altitude 2000 meters above mean sea level
Weight 0.322 kg ( 0.7099 lb)
Power 2 AA batteries
Battery life 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle ( thermometer continuously on)
Hubungi PUTRA BUANA INSTRUMENT
Telp : 02151176451
fax : 021-7302811
CP : irfan 081908101888
email : irfan.syihabudin@ gmail.com
web : http: / / www.buanasurvey.net