Detail Fluke 115 Digital Multimeter Call Irfan 02151176451
Fluke 115 Digital Multimeter Call Irfan 02151176451
Digital Multimeter Fluke 115
Large white LED backlight to work in poorly lit areas
Resistance and continuity
Min/ Max/ Average to record signal fluctuations
CAT III 600 V safety rated
Safety conformance
All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜ V listed and VDE.
Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital: 6, 000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating Temperature -10 ° C to + 50 ° C
Storage Temperature -40 ° C to + 60 ° C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life 400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2
DC volts
Range/ Resolution: 6.000 V / 0.001 V
Range/ Resolution: 60.00 V / 0.01 V
Range/ Resolution: 600.00 V / 0.1 V
Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2
AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz)
AC volts1 true-rms
Range/ Resolution: 6.000 V / 0.001 V
Range/ Resolution: 60.00 V / 0.01 V
Range/ Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz)
Continuity
Range: 600 &
Resolution: 1 &
Accuracy: Beeper on 250 & ; detectsopens or shorts of 500 ¼ s or longer.
Ohms
Range/ Resolution: 600.0 & / 0.1 &
Range/ Resolution: 6.000 k& / 0.001 k&
Range/ Resolution: 60.00 k& / 0.01 k&
Range/ Resolution: 600.0 k& / 0.1 k&
Range/ Resolution: 6.000 M& / 0.001 M&
Accuracy: 0.9 % + 1
Range/ Resolution: 40.00 M& / 0.01 M&
Accuracy: 5 % + 2
Diode Test
Range/ Resolution: 2.00 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance
Range/ Resolution: 1000 nF / 1 nF
Range/ Resolution: 10.00 µ F / 0.01 µ F
Range/ Resolution: 100.0 µ F / 0.1 µ F
Range/ Resolution: 9999 µ F / 1 µ F
Range/ Resolution: 100 µ F to 1000 µ F
Accuracy: 1.9% + 2
Range/ Resolution: > 1000 µ F
Accuracy: 5% + 20%
Lo-Z Capacitance
Range: 1 nF to 500 µ F
Accuracy: 10% + 2 typical
AC amps true-rms ( 45 Hz to 500Hz)
Range/ Resolution: 6.000 A / 0.001 A
Range/ Resolution: 10.00 A / 0.01 A
Accuracy: 1.5% + 3
20 A overload for 30-seconds max
DC amps
Range/ Resolution: 6.000 A / 0.001 A
Range/ Resolution: 10.00 A / 0.01 A
Accuracy: 1.0% + 3
20 A overload for 30-seconds max
Hz ( V or A input) 2
Range/ Resolution: 99.99 Hz / 0.01 Hz
Range/ Resolution: 999.9 Hz / 0.01 Hz
Range/ Resolution: 9.999 kHz / 0.001 kHz
Range/ Resolution: 50 kHz / 0.01 kHz
Accuracy: 0.1% + 2
Notes:
1) All ac voltage ranges except Auto-V/ LoZ are specified from 1 % to 100 % of range. Auto-V/ LoZ is specified from 0.0 V.
2) Temperature uncertainty ( accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/ Resolution: -40 ° F to 752 ° F / 0.2 ° F
2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage
Mechanical & General Specifications
Size 167 x 84 x 46 mm ( 6.57 " x 3.31 " x 1.82 " )
Weight 550 g
Model includes the following:
Installed 9 V battery
Test leads
User manual
HVAC Multimeter Fluke 116 with Temperature and Microamps Call Irfan 02151176451
Built-in thermometer for HVAC applications
Microamps to test flame sensors
Low input impedance: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
Resistance, continuity, frequency and capacitance
Min/ Max/ Average with elapsed time to record signal fluctuations
Compact ergonomic design for one-handed operation
Compatible with optional magnetic hanger ( ToolPak™ )
CAT III 600 V safety rated
Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital: 6, 000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating Temperature -10 ° C to + 50 ° C
Storage Temperature -40 ° C to + 60 ° C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life 400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2
DC volts
Range/ Resolution: 6.000 V / 0.001 V
Range/ Resolution: 60.00 V / 0.01 V
Range/ Resolution: 600.00 V / 0.1 V
Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2
Auto volts
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 2.0 % + 3 ( dc, 45 Hz to 500 Hz)
4.0 % + 3 ( 500 Hz to 1 kHz)
AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz)
2.0 % + 3 ( 500 Hz to 1 kHz)
AC volts1 true-rms
Range/ Resolution: 6.000 V / 0.001 V
Range/ Resolution: 60.00 V / 0.01 V
Range/ Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz)
2.0 % + 3 ( 500 Hz to 1 kHz)
Continuity
Range: 600 &
Resolution: 1 &
Accuracy: Beeper on 250 & ; detects opens or shorts of 500 ¼ s or longer.
Ohms
Range/ Resolution: 600.0 & / 0.1 &
Range/ Resolution: 6.000 k& / 0.001 k&
Range/ Resolution: 60.00 k& / 0.01 k&
Range/ Resolution: 600.0 k& / 0.1 k&
Range/ Resolution: 6.000 M& / 0.001 M&
Accuracy: 0.9 % + 1
Range/ Resolution: 40.00 M& / 0.01 M&
Accuracy: 1.5 % + 2
Diode Test
Range/ Resolution: 2.000 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance
Range/ Resolution: 1000 nF / 1 nF
Range/ Resolution: 10.00 ¼ F / 0.01 ¼ F
Range/ Resolution: 100.0 ¼ F / 0.1 ¼ F
Range/ Resolution: 9999 ¼ F / 1 ¼ F
Range/ Resolution: 100 ¼ F to 1000 ¼ F
Accuracy: 1.9% + 2
Range/ Resolution: > 1000 ¼ F
Accuracy: 5% + 20%
LoZ capacitance
Range: 1 nF to 500 ¼ F
Accuracy: 10% + 2 typical
Temperature2 ( Type-K thermocouple)
Range/ Resolution: -40 ° C to 400 ° C / 0.1 ° C
Accuracy: 1% + 102
Range/ Resolution: -40 ° F to 752 ° F / 0.2 ° F
Accuracy: 1% + 182
AC ¼ amps true-rms ( 45 Hz to 500 Hz)
Range/ Resolution: 600.0 ¼ A / 0.1 ¼ A
Accuracy: 1.0% + 2
DC ¼ amps
Range/ Resolution: 600.0 ¼ A / 0.1 ¼ A
Accuracy: 1.0% + 2
Hz ( V or A input) 2
Range/ Resolution: 99.99 Hz / 0.01 Hz
Range/ Resolution: 999.99 Hz / 0.1 Hz
Range/ Resolution: 9.999 Hz / 0.001 Hz
Range/ Resolution: 50.00 Hz / 0.01 Hz
Accuracy: 0.1% + 2
Notes:
1) All ac voltage ranges except Auto-V/ LoZ are specified from 1 % to 100 % of range. Auto-V/ LoZ is specified from 0.0 V.
2) Temperature uncertainty ( accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/ Resolution: -40 ° F to 752 ° F / 0.2 ° F
Mechanical & General Specifications
Size 167 x 84 x 46 mm ( 6.57 " x 3.31 " x 1.82 " )
Weight 550 g
HVAC Multimeter Model includes the following:
4 mm silicone test lead set
80BK Integrated Temperature probe
Holster
Installed 9 V battery
User manual
Informasi selengkapnya
Hubungi Putra Buana Instrument
T : 02151176451
F : 0217302811
M : 081908101888
CP : Irfan
Tampilkan Lebih Banyak