Detail Fluke 345 Power Quality Clamp Meter Call Irfan 085282731888/ 081908101888
Fluke 345 Power Quality Clamp Meter Call Irfan 085282731888/ 081908101888
This clamp on meter is a combination power analyzer, power quality logger, and clamp meter, and is ideal for monitoring electronic loads.
The Fluke 345 is more than an electric power meter. Combining the functions of a clamp meter, oscilloscope, data logger and digital power meter into one handy device, the Fluke 345 is ideal for working with variable frequency motor drives, high efficiency lighting and other loads using switching electronics.
One of the leading wattage meters of the world, the multi-faceted Fluke 345 is packed with features such as a bright, color display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise and a high EMC immunity design, making the Fluke 345 power analyzer ideal for troubleshooting power quality on switching loads. The internal memory of this electric power meter enables long-term power quality logging for analysis of trends or intermittent problems. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit.
Besides effectively performing basic tasks like measuring wattage, the Fluke 345 power meters offer the ease of use, portability and flexibility needed to resolve most power issues in commercial, industrial and residential settings.
Setup and troubleshoot variable frequency drives and UPS systems - Verify correct operation by measuring key power quality parameters
Harmonics measurements - Uncover harmonic issues that can damage or disrupt critical equipment
Inrush capture - Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
Load studies - Verify electrical system capacity before adding loads
AC/ DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance
Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter
Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics
Verify batteries: Direct measurement of dc ripple ( % ) for battery and dc systems
Troubleshoot harmonics: Analyze and log harmonics digitally or graphically
Inrush current: Capture and analyze nuisance tripping, from 3 seconds to 300 seconds
Easy to use: Easily confirm power meter setup with large backlit color display of waveforms and trends
3-Phase power: Built in capability for balanced loads
View graphs and generate reports: Use power analyzer with included Power Log software
Display
Color transmissive LCD 320 x 240 pixels ( 70 mm diagonal) with 2 level backlight
Power supply
Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6
Battery life typically
> 10 hours ( backlight on full)
> 12 hours ( backlight reduced)
Battery Eliminator BE345
Input 110/ 230 V 50/ 60 Hz
Output 15 V dc, 300 mA
Ambient conditions ( For indoor use only)
Reference conditions
All accuracies stated at 23Ú C ± 1Ú C ( 73.4 ° F ± 1.8 ° F)
Operating temperature
0 ° C to 50 ° C ( 32 ° F to 122 ° F)
Temperature coefficient of current
d ± 0.15 % of rdg per ° C
Temperature coefficient of voltage
d ± 0.15 % of rdg per ° C
Maximum relative humidity
80 % for temperatures up to 31 ° C ( 87 ° F) decreasing linearly to 50 % relative humidity at 40 ° C ( 104 ° F)
Maximum operating altitude
2000 m
Electrical safety
Maximum safe working voltages
Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2
Protection IP40; EN60529
Current measurement
600 V ac rms or dc between uninsulated conductor and ground
Voltage measurement
600 V ac rms or dc between either input terminal and ground, or 825 V between energized phase voltages ( delta power config.)
EMC
Emission
IEC/ EN 61326-1: 1997 class A
Immunity
IEC/ EN 61326-1: 1997 Annex C Performance Criterion B
Mechanical
Dimensions ( length x width x depth)
300 mm x 98 mm x 52 mm ( 12 in x 3.75 in x 2 in)
Weight including batteries
820 g/ 1.8 lb
Jaw opening
60 mm
Jaw capacity
58 mm diameter
Cleaning
The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents.
Electrical data
All accuracies stated at 23 ° C ± 1 ° C ( 73.4 ° F ± 1.8 ° F) . See Ambient conditions specifications for temperature coefficients.
Current measurement ( dc, dc rms, ac rms)
Measuring range
0 to 2000 A dc or 1400 ac rms
Autorange facility
40 A / 400 A / 2000 A
Resolution
10 mA in 40 A range
100 mA in 400 A range
1 A in 2000 A range
Accuracy: DC and dc rms
I > 10 A: ± 1.5 % rdg ± 5 digits
I 10 A: ± 3 % rdg ± 5 digits
I 10 A: ± 5 % rdg ± 5 digits
I 10 A: ± 2 % rdg ± 5 digits
I < 10 A: ± 0.5 AHr
Accuracy: CF ( Crest Factor)
1.1 d CF < 3: ± 3 % rdg ± 5 digits
3 d CF < 5: ± 5 % rdg ± 5 digits
Resolution: 0.01
Accuracy: RPL ( Ripple)
2 % d RPL 2 A
All measurements dc and 15 Hz to 1 kHz
Maximum overload 10, 000 A or rms x frequency 1 V: ± 1 % rdg ± 5 digits
V 1 V: ± 3 % rdg ± 5 digits
V 1 V: ± 5 % rdg ± 5 digits
V < 1 V: ± 0.03 V
Accuracy: CF ( Crest Factor)
1.1 d CF < 3: ± 3 % rdg ± 5 digits
3 d CF < 5: ± 5 % rdg ± 5 digits
Resolution: 0.01
Accuracy: RPL ( Ripple)
2 % d RPL 0.2 V
All measurements dc and 15 Hz to 1 kHz
Maximum overload 1, 000 V rms
Volts rms is a true-rms measurement ( ac + dc)
Harmonics
THD ( Total Harmonic Distortion)
1 % d THD < 100 % : ± 3 % rdg ± 5 digits
100 % d THD < 600 % : ± 5 % rdg ± 5 digits
Resolution: 0.1 %
DF ( Distortion Factor)
1 % d DF < 100 % : ± 3 % rdg ± 5 digits
Resolution: 0.1 %
H02 d Vharm 1V
Watts measurement ( single- and three-phase) ( dc, dc rms, ac rms)
Measuring range
0 to 1650 kW dc or 1200 kW ac
Autoranging facility
4 kW, 40 kW, 400 kW, 1650 kW
Resolution
1 W in 4 kW
10 W in 40 kW
100 W in 400 kW
1 kW in 1200 kW
Accuracy
2.5 % rdg ± 5 digits
W1Ø < 2 kW ± 0.08 kW
W3Ø 2 kVA: 2.5 % rdg ± 5 digits
VA 4 kVAR: ± 2.5 % rdg ± 5 digits
VAR < 4 kVAR: ± 0.25 kVAR
Power factor range
0.3 < PF 2 kWHr: ± 3 % ± 5 digits
kWHr < 2 kWHr: ± 0.08 kWHr
All Watts / VA / VAR / PF measurements
Frequency range: DC and 15 Hz to 1 kHz
Current range: 10 A to 1400 A rms
Voltage range: 1 V to 825 V rms
Maximum input: 825 V rms/ 1400 A rms
Maximum overload: 1000 V rms/ 10, 000 A All measurements dc and 15 Hz to 1 kHz. Maximum overload 10, 000 A or rms x frequency 10 A: ± 5 % rdg ± 1 pixel
I < 10 A: ± 0.5 A
All measurements dc and 15 Hz to 1 kHz
Maximum overload
Maximum overload 10, 000 A or rms x frequency < 400, 000
Amps rms is a true-rms measurement ( ac + dc)
Capture time
1 s, 3 s, 10 s, 30 s, 100 s, and 300 s
Maximum sampling rate
15.625 kHz
Interface
USB Interface to a PC
Power Log software for download, analysis and reporting
345 Upgrade Utility for installing a new firmware version
Logging Memory
Logging areas
Three areas that can be used individually or combined into one large area
Averaging periods
1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, and custom
Logging Times
Volts and current mode
Average time Logging time ( 1 area)
1 s 1 h 49 m
2 s 3 h 38 m
5 s 9 h 6 m
10 s 18 h 12 m
30 s 2 d 6 h 36 m
1 min 4 d 13 h 12 m
5 min 22 d 18 h 0 m
10 min 45 d 12 h 0 m
15 min 68 d 6 h 0 m
Logging time ( 3 areas)
1 s 5 h 12 m
2 s 10 h 24 m
5 s 1 d 2 h 00 m
10 s 2 d 4 h 00 m
30 s 6 d 12 h 1 m
1 min 13 d 0 h 12 m
5 min 65 d 0 h 15 m
10 min 130 d 0 h 30 m
15 min 195 d 0 h 45 m
V & A harmonics mode
Average time Logging time ( 1 area)
1 s 0 h 34 m
2 s 1 h 8 m
5 s 2 h 52 m
10 s 5 h 44 m
30 s 17 h 13 m
1 m 1 d 10 h 26 m
5 m 7 d 4 h 10 m
10 m 14 d 8 h 20 m
15 m 21 d 12 h 30 m
Logging time ( 3 areas)
1 s 1 h 38 m
2 s 3 h 16 m
5 s 8 h 11 m
10 s 16 h 23 m
30 s 2 d 1 h 11 m
1 m 4 d 2 h 23 m
5 m 20 d 11 h 25 m
10 m 81 d 0 h 50 m
15 m 121 d 13 h 15 m
single- and three-phase power mode
Average time Logging time ( 1 area)
1 s 1 h 40 m
2 s 3 h 21 m
5 s 8 h 22 m
10 s 16 h 45 m
30 s 2 d 2 h 17 m
1 m 4 d 4 h 35 m
5 m 20 d 22 h 55 m
10 m 41 d 21 h 50 m
15 m 62 d 20 h 45 m
Logging time ( 3 areas)
1 s 4 h 47 m
2 s 9 h 34 m
5 s 23 h 57 m
10 s 1 d 23 h 54 m
30 s 5 d 23 h 25 m
1 m 11 d 23 h 25 m
5 m 59 d 21 h 5 m
10 m 119 d 18 h 10 m
15 m 179 d 15 h 15 m
Power Quality Clamp Meter fluke 345
Includes:
345 Power Quality Clamp Meter
Soft carrying case
Power Log software
Test leads
Alligator clips
Test probes
USB cable
International ac adapter / battery eliminator
Printed English language user manual
Multi-language manual CD
Hubungi Putra Buana Instrument
Jl. Ciledug Raya Komplek. Taman Surya Buana Blok L19 - Kreo - Cipadu, Ciledug - Tangerang 15155
CP : Irfan Syihabudin
XL : 081908101888
AS : 085282731888
Tampilkan Lebih Banyak