Back to Top

Hi, Guest!
  • FLUKE
  • Fluke 317/ 319, True RMS Clamp Meter Clamp Meters call Irfan 02151176451

Fluke 317/ 319, True RMS Clamp Meter Clamp Meters call Irfan 02151176451

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
13 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Fluke 317/ 319, True RMS Clamp Meter Clamp Meters Call Irfan 02151176451

True RMS Clamp Meter Fluke 317/ 319 Clamp Meters call Irfan 02151176451 These affordable instruments combine a compact package with a strong feature set: Special 40A high accuracy AC/ DC high measure, 1.6% accuracy, 0.01A resolution Small body and jaws fit perfectly in your hand and into tight places Large, backlit display is easy-to-see in less than ideal conditions In-rush current function ( 319) for measuring starting current for motors, lighting, etc. Measuring current Frequency ( 319) Resolution up to 0.01A and 0.1 V Measures AC/ DC current to 1000 A ( 319) Measures AC/ DC volts to 600 V Resistance measurement to 4000 © Continuity for quick checking of shorts Auto-shut-off maximizes battery life so the meter works when you need it Display hold function General Specifications Digital Display 6000 count resolution Low Battery Indication Displays a signal when the batteries are below their required voltage Power Source Three AAA IEC LR03 batteries Clamp Opening Size 1.45 in ( 37 mm) Jaw Diameter 1.45 in ( 37 mm) Dimensions ( L x W x H) 6.39 in x 2.29 in x 1.20 in ( 162.4 mm x 58.25 mm x 30.5 mm) Weight approximately 13.5 oz ( 384 g) ( batteries included) Auto Range Available in Ohms Safety CE EN/ IEC 61010-1 and IEC 61010-2-032 Measurement Category: 600V CAT III 317 Electrical Specifications Current AC Range 40.00 A, 600.0 A Resolution 0.01 A, 0.1 A Accuracy 1.6% ± 6 digit ( 50-60 Hz) { 40 A} 2.5% ± 8 digit ( 60-500 Hz) { 40 A} 1.5% ± 5 digit ( 50-60 Hz) { 600 A} 2.5% ± 5 digit ( 60-500 Hz) { 600 A} Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A AC response rms Current DC Range 40.00 A, 600.0 A Resolution 0.01 A, 0.1 A Accuracy 1.6% ± 6 digit ( 40 A) 1.5% ± 5 digit ( 600 A) Voltage AC Range 600.0 V Resolution 0.1 V Accuracy 1.5% ± 5 digit ( 20-500Hz) AC response rms Voltage DC Range 600.0 V Resolution 0.1 V Accuracy 1% ± 4 digit Resistance Range 400.0 © , 4000 © Resolution 0.1 © , 1 © Accuracy 1% ± 5 digit Continuity d 30 © Inrush Integration time N/ A Frequency Range N/ A Accuracy N/ A Trigger Level N/ A 319 Electrical Specifications Current AC Range 40.00 A, 600.0 A, 1000 A Resolution 0.01 A, 0.1 A, 1 A Accuracy 1.6% ± 6 digit ( 50-60 Hz) { 40 A} 2.5% ± 8 digit ( 60-500 Hz) { 40 A} 1.5% ± 5 digit ( 50-60 Hz) { 600/ 1000 A} 2.5% ± 5 digit ( 60-500 Hz) { 600/ 1000 A} Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A AC response rms Current DC Range 40.00 A, 600.0 A, 1000 A Resolution 0.01 A, 0.1 A, 1 A Accuracy 1.6% ± 6 digit ( 40 A) 1.5% ± 5 digit ( 600/ 1000 A) Voltage AC Range 600.0 V Resolution 0.1 V Accuracy 1.5% ± 5 digit ( 20-500Hz) AC response rms Voltage DC Range 600.0 V Resolution 0.1 V Accuracy 1% ± 4 digit Resistance Range 400.0 © 4000 © Resolution 0.1 © 1 © Accuracy 1% ± 5 digit Continuity d 30 © Inrush Integration time 100 ms Frequency Range 5.0 - 500.0 Hz Accuracy 0.5% ± 5 digit Trigger Level 10 - 100 Hz e 5 A, 5 - 10 Hz, 100 - 500 Hz e 10 A The accuracy specifications aply at 73 ° F ± 41 ° F ( 23 ° C ± 5 ° C) Below 64 ° F and above 82 ° F ( 18 ° C and above 28 ° C) accuracy degrades at ( 0.1) times specification per ° C. True rms for ac V and ac A accuracy is specified from 5% to 100% of range. Environmental Specifications Operating Temperature 14° F to 122° F ( -10 ° C to 50 ° C) Storage Temperature -40 ° F to 140 ° F ( -40 ° C to 60 ° C) Operating Humidity Non condensing ( < 50 ° F) ( < 10 ° C) 90 % RH ( 50 ° F to 86 ° F) ( 10 ° C to 30 ° C) 75 % RH ( 86 ° F to 104 ° F) ( 30 ° C to 40 ° C) 45 % RH ( 104 ° F to 122 ° F) ( 40 ° C to 50 ° C) ( Without Condensation) Operating Altitude 1 mile ( 2000 meters) above mean sea level Storage Altitude 7 miles ( 12, 000 meters) above mean sea level IP Rating IP40 Vibration Requirements Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis Drop Test Requirements 3 ft ( 1 m) drop test, six sides, oak floor EMI, RFI, EMC Instrument unspecified for use in EMC field e 0.1 V/ m Temperature Coefficients 0.1x ( specified accuracy) / ° C ( 82° F) ( 28 ° C) Model Name Description Fluke 317/ 319 The Meter ships with: Test Leads Soft Carrying Case Three AAA batteries ( Installed) 317/ 319 User Manual call irfan 021511476451, email : irfan.syihabudin@ gmail.com untuk informasi lebih jelasnya silahkan hubungi marketing kami, call : 02151176451 fax : 021-7302811 CP : irfan 02151176451 email : irfan.syihabudin@ gmail.com web : http: / / www.buanasurvey.com
Tampilkan Lebih Banyak