Back to Top

Hi, Guest!
  • FLUKE
  • Fluke 114, Digital Multimeter Call irfan 02151176451

Fluke 114, Digital Multimeter Call irfan 02151176451

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Fluke 114, Digital Multimeter Call Irfan 02151176451

Fluke 114, Digital Multimeter Call irfan 02151176451 Feature : AutoVolt: automatic ac/ dc voltage selection Large white LED backlight to work in poorly lit areas Resistance and continuity Min/ Max/ Average to record signal fluctuations CAT III 600 V safety rated Safety conformance All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜ V listed and VDE. Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 Display Digital: 6, 000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating Temperature -10 ° C to + 50 ° C Storage Temperature -40 ° C to + 60 ° C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2 DC volts Range/ Resolution: 6.000 V / 0.001 V Range/ Resolution: 60.00 V / 0.01 V Range/ Resolution: 600.00 V / 0.1 V Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2 Auto volts Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0 % + 3 ( dc, 45 Hz to 500 Hz) 4.0 % + 3 ( 500 Hz to 1 kHz) AC millivolts1 true-rms Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz) AC volts1 true-rms Range/ Resolution: 6.000 V / 0.001 V Range/ Resolution: 60.00 V / 0.01 V Range/ Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz) Continuity Range: 600 & Resolution: 1 & Accuracy: Beeper on 250 & ; detectsopens or shorts of 500 ¼ s or longer. Ohms Range/ Resolution: 600.0 & / 0.1 & Range/ Resolution: 6.000 k& / 0.001 k& Range/ Resolution: 60.00 k& / 0.01 k& Range/ Resolution: 600.0 k& / 0.1 k& Range/ Resolution: 6.000 M& / 0.001 M& Accuracy: 0.9 % + 1 Range/ Resolution: 40.00 M& / 0.01 M& Accuracy: 5 % + 2 Notes: 1) All ac voltage ranges except Auto-V/ LoZ are specified from 1 % to 100 % of range. Auto-V/ LoZ is specified from 0.0 V. 2) Temperature uncertainty ( accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/ Resolution: -40 ° F to 752 ° F / 0.2 ° F Mechanical & General Specifications Size 167 x 84 x 46 mm ( 6.57 " x 3.31 " x 1.82 " ) Weight 550 g Model includes the following: Holster Installed 9 V battery Test leads User manual Informasi selengkapnya Hubungi Putra Buana Instrument T : 02151176451 F : 0217302811 M : 081908101888 CP : Irfan Mail : irfan.syihabudin@ gmail.com
Tampilkan Lebih Banyak