Back to Top

Hi, Guest!
  • FLUKE
  • Fluke 1507/ 1503, Insulation Resistance Testers Call Irfan 02151176451

Fluke 1507/ 1503, Insulation Resistance Testers Call Irfan 02151176451

Update Terakhir
:
15 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
37 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Fluke 1507/ 1503, Insulation Resistance Testers Call Irfan 02151176451

Fluke 1507/ 1503, Insulation Resistance Testers Call Irfan 02151176451 Features: Insulation test range: 1507: 0.01 M& to 10 G& 1503: 0.1 M& to 2000 M& Insulation test voltages: 1507: 50 V, 100 V, 250 V, 500 V, 1000 V 1503: 500 V, 1000 V Save both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio ( only available on the1507) Make repetitive tests simple and easy with the 1507’ s Compare ( Pass/ Fail) function ( only available on the 1507) Repetitive or hard-to-reach testing is easy with the remote test probe Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection Auto-discharge of capacitive voltage for added user protection AC/ DC voltage: 0.1 V to 600 V 200 mA Continuity Resistance: 0.01 & to 20.00 k& Save battery power with auto power off Read measurements easily with large, backlit display CAT IV 600 V overvoltage category rating for added user protection Remote probe, test leads, probes and alligator clips included with each tester Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work Four AA alkaline batteries ( NEDA 15 A or IEC LR6) for at least 1000 insulation tests AC/ DC Voltage Measurement Accuracy Range 600.0 V Resolution 0.1 V 50 Hz to 400 Hz ± ( % of Rdg + Digits) ± ( 2 % + 3) Input impedance 3 M© ( nominal) , 60 dB at dc, 50 or 60 Hz Overload Protection 600 V rms or dc Earth bond resistance measurement Range/ Resolution 20.00 © 0.01 © 200.0 © 0.1 © 2000 © 1.0 © 20.00 k© 0.01 k© Accuracy ± ( 1.5 % + 3) Overload Protection 2 V rms or dc Open Circuit Test Voltage > 4.0 V, 200.0 mA Insulation specifications Measurement Range 1507: 0.01 M© to 10 G© 1503: 0.01 M© to 2000 M© Test voltage 1507: 50 V, 100 V, 250 V, 500 V, 1000 V 1503: 500 V, 1000V Test Voltage Accuracy + 20 % , - 0 % Short circuit current 1 mA nominal Auto Discharge Discharge time 30 V prior to initialization of test Maximum Capacitive Load Operable with up to 1 µ F load Measure Accuracy: 50 V: ± ( 3 % + 5) 100 V: ± ( 3 % + 5) 250 V: ± ( 1.5 % + 5) 500 V: ± ( 1.5 % + 5) 1000 V: ± ( 1.5 % + 5) to 2000 M© , ± ( 10 % + 3) above 2000 M© General Specifications Maximum voltage applied to any terminal: 600 V ac rms or dc Storage Temperature -40 ° C to 60 ° C ( -40 ° F to 140 ° F) Operating Temperature -20 ° C to 55 ° C ( -4 ° F to 131 ° F) Temperature Coefficient 0.05 x ( specified accuracy) per ° C for temperatures 28 ° C ( 82 ° F) Relative Humidity 0 % to 95 % @ 10 ° C to 30 ° C ( 50 ° F to 86 ° F) 0 % to 75 % @ 30 ° C to 40 ° C ( 86 ° F to 104 ° F) 0 % to 40 % @ 40 ° C to 55 ° C ( 104 ° F to 131 ° F) Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument Shock 1 meter drop per IEC 61010-1 2nd Edition ( 1 meter drop test, six sides, oak floor) Electromagnetic compatibility: In an RF field of 3 V/ M, accuracy = specified accuracy ( EN 61326-1: 1997) Safety Complies with ANSI/ ISA 82.02.01 ( 61010-1) 2004, CAN/ CSA-C22.2 NO. 61010-1-04, and IEC/ EN 61010-1 2nd Edition for measurement category IV 600 V ( CAT IV) Certifications: CSA per standard CSA/ CAN C22.2 No. 61010.1-04; TUV per standard IEC/ EN 61010-1 2nd Edition Batteries Four AA batteries ( NEDA 15A or IEC LR6) Battery Life Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 M© with a duty cycle of 5 seconds on and 25 seconds off. Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 © with a duty cycle of 5 seconds on and 25 seconds off. Size 5.0 cm H x 10.0 cm W x 20.3 cm L ( 1.97 in H x 3.94 in W x 8.00 in L) Weight 550 g ( 1.2 lb) IP Rating IP40 Altitude Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V Non-operating ( storage) : 12, 000 m Over-range capability: 110 % of range Included accessories: TL224 Test Leads, TP74 Test Probes, clips PN 1958654 ( red) and PN 1958646 ( black) , holster and remote probe Insulation Tester FLUKE 1503/ 1507 Includes: Remote probe Test leads Test probes Alligator clips User documentation Informasi selengkapnya Hubungi Putra Buana Instrument T : 02151176451 F : 0217302811 M : 081908101888 CP : Irfan
Tampilkan Lebih Banyak