Back to Top

Hi, Guest!
  • FLUKE
  • Fluke 568 and 566, Infrared and Contact Thermometer Call Irfan 02151176451

Fluke 568 and 566, Infrared and Contact Thermometer Call Irfan 02151176451

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
7 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Fluke 568 And 566, Infrared And Contact Thermometer Call Irfan 02151176451

Fluke 568 and 566, Infrared and Contact Thermometer Call Irfan 02151176451 Overview: Two-in-one IR and contact thermometers with an innovative dot matrix display. With a simple, 3-button on-screen menu interface ( in 6 languages) the Fluke 568 and 566 digital laser thermometers make even complex measurements easy. Quickly navigate advanced features to adjust emissivity, start data logging, or turn on and off alarms - with just a few pushes of a button. With a rugged, easy-to-use, ergonomic design, the Fluke 568 and 566 two-in-one contact and non contact thermometers can stand up to tough industrial, electrical, and mechanical environments. These tools go beyond other IR thermometers ( or pyrometers) , helping you work more efficiently in more applications. Added functionality available only on the 568: Easily trend and analyze data with included FlukeView® Forms software Quickly download stored data with USB connection See your data right away without leaving the site, using the USB and your laptop Extend your battery life by powering the digital thermometer from your laptop via the USB Features and benefits of the 568 and 566: Measure -40 ° C to 800 ° C / -40 ° F to 1472 ° F ( 568) or -40 ° C to 650 ° C/ -40 ° F to 1202 ° F ( 566) Easily access advanced features with the soft-key buttons and dot-matrix display Measure smaller objects from further away, with a distance-to-spot ratio of 50: 1 ( 568) or 30: 1 ( 566) Compatibility with all standard miniconnector Type-K thermocouples allow you to preserve your thermocouple investments Confidently measure a wide variety of surfaces, with the adjustable emissivity feature, including a built-in material table Capture multiple points of data ( up to 99 with the 568, and 20 with the 566) , for downloading and recalling later Easily adapt to lighting conditions with 2 levels of backlight Audible and visual alarms instantly alert you to measurements outside of your set limits Quickly identify problems with the MIN, MAX, AVG, and DIF functions Make contact thermometer measurements right away with the included Type-K thermocouple bead probe Confidently troubleshoot equipment with 1 % measurement accuracy Versatile interface with 6 languages from which to choose Product specifications Infrared temperature range 566: -40 ° C to 650 ° C ( -40 ° F to 1202 ° F) 568: -40 ° C to 800 ° C ( -40 ° F to 1472 ° F) Infrared accuracy 0 ° C ( 32 ° F) : ± 1 % or ± 1.0 ° C ( ± 2.0 ° F) , whichever is greater Display resolution 0.1 ° C / 0.1 ° F Infrared spectral response 8 µ m to 14 µ m Infrared response time < 500 msec Thermocouple Type-K input temperature range -270 ° C to 1372 ° C ( -454 ° F to 2501 ° F) Thermocouple Type-K input accuracy -270° C to -40° C: ± ( 1 ° C + 0.2 ° / 1 ° C) ( -454 ° F to -40 ° F: ± ( 2 ° F + 0.2 ° / 1 ° F) ) -40° C to 1372° C: ± 1 % or 1 ° C ( -40 ° F to 2501 ° F: ± 1 % or 2 ° F) , whichever is greater D: S ( distance to measurement spot size) 566: 30: 1 568: 50: 1 Laser sighting Single-point laser < 1 mw output Class 2 ( II) operation, 630 nm to 670 nm Minimum spot size 19 mm ( 0.75 in) Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 Data storage with Date/ Time stamp 566: 20 points 568: 99 points PC Interface and cable 566: None 568: USB 2.0 with FlukeView® Forms software Hi/ Low alarms Audible and two-color visual Min/ Max/ Avg/ Dif Yes Display Dot matrix 98 x 96 pixels with function menus Backlight Two levels, normal and extra bright for darker environments Trigger lock Yes Switchable Celsius and Fahrenheit Yes Power 566: 2 AA/ LR6 Batteries 568: 2 AA/ LR6 Batteries and USB when used with a PC Battery life If used continuously: laser and backlight on, 12 hours; laser and backlight off, 100 hours Operating temperature 0 ° C to 50 ° C ( 32 ° F to 122 ° F) Storage temperature -20 ° C to 60 ° C ( -40 ° F to 140 ° F) Bead thermocouple Type-K range -40 ° C to 260 ° C ( -40 ° F to 500 ° F) Bead thermocouple Type-K accuracy ± 1.1 ° C ( 2.0 ° F) from 0 ° C to 260 ° C ( 32 ° F to 500 ° F) , typically within 1.1 ° C ( 2.0 ° F) from -40 ° C to 0 ° C ( -40 ° F to 32 ° F) Infrared and Contact Thermometer Fluke 566 includes: Thermocouple K bead probe Durable hard case 2 AA batteries Getting Started guide in 6 languages User’ s Manual on CD in 6 languages ( English, Spanish, French, German, Portuguese, and Simplified Chinese) Infrared and Contact Thermometer Fluke 568 includes: Thermocouple K bead probe Durable hard case 2 AA batteries Getting Started guide in 6 languages USB cable FlukeView® Forms software on CD User’ s Manual on CD in 6 languages ( English, Spanish, French, German, Portuguese, and Simplified Chinese) Informasi selengkapnya Hubungi Putra Buana Instrument T : 02151176451 F : 0217302811 M : 081908101888 CP : Irfan
Tampilkan Lebih Banyak