Detail Fluke 787 ProcessMeter™ Call Irfan 02151176451
Fluke 787 ProcessMeter™ call irfan 02151176451
Double Your Power
The Fluke 787 was the first tool to combine a DMM and a loop calibrator to give process technicians double the power in one tool. Now it’ s even better, the range is extended with the new Fluke 789 – the ultimate loop calibration multimeter. The Fluke 789 has a 24-Volt loop supply reducing the need for taking a separate power supply when doing offline transmitter testing. And with its built-in, selectable 250-Ohm Hart® resistor, it also eliminates the need to carry a separate resistor with you. Now process technicians can do a lot more while carrying a lot less.
Specifications
Current Measurement
Range: 0-1 A AC or DC
Resolution: 1 mA
Accuracy: 0.2% + 2 LSD ( DC)
Range: 0-30 mA
Resolution: 0.001 mA
Accuracy: 0.05% + 2 LSD
Current Sourcing
Range: 0-20 mA or 4-20 mA
Resolution: 0.05% of span
Drive Capability: 24 V Compliance or 1200 © @ 20 mA
Frequency
to 19.999 kHz, 0.005% + 1 LSD
Continuity
Beeps for resistance < 100 ©
Voltage measurement
Range: 0-1000 V AC ( true-rms) or DC
Resolution: 0.1 mV to 1.0 V
Accuracy: 0.1% Rdg + 1 LSD ( VDC)
Resistance measurement
to 40 M© , 0.2% + 1 LSD
Diode test
2.0 V shows diode voltage drop
Display current and % of span
Yes
Auto step, auto ramp
Yes
Environmental Specifications
Operating Temperature
-20 º C to 55 º C
Storage Temperature
-40 º C to 60 º C
Humidity ( Without Condensation)
95% up to 30 º C
75% up to 40 º C
45% up to 50 º C
35% up to 55 º C
Temperature Coefficient
0.05 x ( specified accuracy) per º C ( for temperatures 28 º C)
Safety Specifications
Electrical Safety
Designed in accordance with IEC 1010-1, ANSI/ ISA S82.01-1994 and CAN/ CSA C22.2 No. 1010.1-92
Overvoltage category
IEC 1010-1 CAT III 1000 V
IEC 1010-1 CAT IV 600 V
Maximum voltage
1000 V rms
Mechanical & General Specifications
Size
50 x 100 x 203 mm ( 1.25" H x 3.41" W x 7.35" L)
Weight
610 g ( 1.6 lbs)
Batteries
4 AA Alkaline batteries
Warranty
3 years
Battery Life
140 hours typical ( measurement) , 10 hours typical ( sourcing 20 mA)
Shock & Vibration
Random, 2 g, 5-500 Hz
1 meter drop test
Specifications
Current Measurement
Range: 0-1 A AC or DC
Resolution: 1 mA
Accuracy: 0.2% + 2 LSD ( DC)
Range: 0-30 mA
Resolution: 0.001 mA
Accuracy: 0.05% + 2 LSD
Current Sourcing
Range: 0-20 mA or 4-20 mA
Resolution: 0.05% of span
Drive Capability: 24 V Compliance or 1200 © @ 20 mA
Frequency
to 19.999 kHz, 0.005% + 1 LSD
Continuity
Beeps for resistance < 100 ©
Voltage measurement
Range: 0-1000 V AC ( true-rms) or DC
Resolution: 0.1 mV to 1.0 V
Accuracy: 0.1% Rdg + 1 LSD ( VDC)
Resistance measurement
to 40 M© , 0.2% + 1 LSD
Diode test
2.0 V shows diode voltage drop
Display current and % of span
Yes
Auto step, auto ramp
Yes
Environmental Specifications
Operating Temperature
-20 º C to 55 º C
Storage Temperature
-40 º C to 60 º C
Humidity ( Without Condensation)
95% up to 30 º C
75% up to 40 º C
45% up to 50 º C
35% up to 55 º C
Temperature Coefficient
0.05 x ( specified accuracy) per º C ( for temperatures 28 º C)
Safety Specifications
Electrical Safety
Designed in accordance with IEC 1010-1, ANSI/ ISA S82.01-1994 and CAN/ CSA C22.2 No. 1010.1-92
Overvoltage category
IEC 1010-1 CAT III 1000 V
IEC 1010-1 CAT IV 600 V
Maximum voltage
1000 V rms
Mechanical & General Specifications
Size
50 x 100 x 203 mm ( 1.25" H x 3.41" W x 7.35" L)
Weight
610 g ( 1.6 lbs)
Batteries
4 AA Alkaline batteries
Battery Life
140 hours typical ( measurement) , 10 hours typical ( sourcing 20 mA)
Shock & Vibration
Random, 2 g, 5-500 Hz
1 meter drop test