Detail PROCESSMETER™ FLUKE 789 CALL IRFAN 02151176451
PROCESSMETER™ FLUKE 789 CALL IRFAN 02151176451
Features of the Fluke 789
24 V Loop power supply
Very large dual display
Enhanced backlight with 2 brightness settings
1200 Ohm drive capability on mA source
HART mode setting with loop power and a built-in 250 ohm resistor
0% and 100 % buttons to toggle between 4 and 20 mA sourcing for a quick span check
Externally accessible fuses for easy replacement
Infrared-port to process data in FlukeView Forms ( V2.1) software
Fluke 789 features that are also included in the Fluke 787
Precision 1000 V, 440 mA True-RMS digital Multimeter
0.1% dc voltage accuracy
0.05% dc current accuracy
Frequency measurement to 20 kHz
Min/ Max/ Average/ Hold/ Relative modes
Diode Test and Continuity Beeper
Simultaneous mA and % of scale readout
20 mA DC current source / loop calibrator / simulator
Manual Step ( 100% , 25% , Coarse, Fine) plus Auto Step and Auto Ramp
Externally accessible battery for easy battery changes
Safety Conformance
Meets 1000 Volt EN61010-1 CAT III standards and 600 Volt EN61010-1 CAT IV standards.
Specifications
Current Measurement
Range: 0-1 A AC or DC
Resolution: 1 mA
Accuracy: 0.2% + 2 LSD ( DC)
Range: 0-30 mA
Resolution: 0.001 mA
Accuracy: 0.05% + 2 LSD
Current Sourcing
Range: 0-20 mA or 4-20 mA
Resolution: 0.05% of span
Drive Capability: 24 V Compliance or 1200 © @ 20 mA
Frequency
to 19.999 kHz, 0.005% + 1 LSD
Continuity
Beeps for resistance < 100 ©
Voltage measurement
Range: 0-1000 V AC ( true-rms) or DC
Resolution: 0.1 mV to 1.0 V
Accuracy: 0.1% Rdg + 1 LSD ( VDC)
Resistance measurement
to 40 M© , 0.2% + 1 LSD
Diode test
2.0 V shows diode voltage drop
Display current and % of span
Yes
Auto step, auto ramp
Yes
Environmental Specifications
Operating Temperature
-20 º C to 55 º C
Storage Temperature
-40 º C to 60 º C
Humidity ( Without Condensation)
95% up to 30 º C
75% up to 40 º C
45% up to 50 º C
35% up to 55 º C
Temperature Coefficient
0.05 x ( specified accuracy) per º C ( for temperatures 28 º C)
Safety Specifications
Electrical Safety
Designed in accordance with IEC 1010-1, ANSI/ ISA S82.01-1994 and CAN/ CSA C22.2 No. 1010.1-92
Overvoltage category
IEC 1010-1 CAT III 1000 V
IEC 1010-1 CAT IV 600 V
Maximum voltage
1000 V rms
Mechanical & General Specifications
Size
50 x 100 x 203 mm ( 1.25 " H x 3.41 " W x 7.35 " L)
Weight
610 g ( 1.6 lbs)
Batteries
4 AA Alkaline batteries
Battery Life
140 hours typical ( measurement) , 10 hours typical ( sourcing 20 mA)
Shock & Vibration
Random, 2 g, 5-500 Hz
1 meter drop test
ProcessMeter Fluke 789
Include :
AC72 Alligator Clips
Four AA 1.5 V alkaline battery ( installed)
TL71 Safety-Designed Test lead Set
Users Manual and Quick Reference Guide
Hubungi toko DINS ( Digital Instruments)
Jl. Ciledug Raya Komplek. Taman Surya Buana Blok L19 - Kreo - Cipadu, Ciledug - Tangerang 15155
CP : Irfan Syihabudin
XL : 081908101888
AS : 085282731888
ProcessMeter™ Fluke 789 Call Syihabudin 085282731888/ 081908101888
Features of the Fluke 789
24 V Loop power supply
Very large dual display
Enhanced backlight with 2 brightness settings
1200 Ohm drive capability on mA source
HART mode setting with loop power and a built-in 250 ohm resistor
0% and 100 % buttons to toggle between 4 and 20 mA sourcing for a quick span check
Externally accessible fuses for easy replacement
Infrared-port to process data in FlukeView Forms ( V2.1) software
Fluke 789 features that are also included in the Fluke 787
Precision 1000 V, 440 mA True-RMS digital Multimeter
0.1% dc voltage accuracy
0.05% dc current accuracy
Frequency measurement to 20 kHz
Min/ Max/ Average/ Hold/ Relative modes
Diode Test and Continuity Beeper
Simultaneous mA and % of scale readout
20 mA DC current source / loop calibrator / simulator
Manual Step ( 100% , 25% , Coarse, Fine) plus Auto Step and Auto Ramp
Externally accessible battery for easy battery changes
Safety Conformance
Meets 1000 Volt EN61010-1 CAT III standards and 600 Volt EN61010-1 CAT IV standards.
Specifications
Current Measurement
Range: 0-1 A AC or DC
Resolution: 1 mA
Accuracy: 0.2% + 2 LSD ( DC)
Range: 0-30 mA
Resolution: 0.001 mA
Accuracy: 0.05% + 2 LSD
Current Sourcing
Range: 0-20 mA or 4-20 mA
Resolution: 0.05% of span
Drive Capability: 24 V Compliance or 1200 © @ 20 mA
Frequency
to 19.999 kHz, 0.005% + 1 LSD
Continuity
Beeps for resistance < 100 ©
Voltage measurement
Range: 0-1000 V AC ( true-rms) or DC
Resolution: 0.1 mV to 1.0 V
Accuracy: 0.1% Rdg + 1 LSD ( VDC)
Resistance measurement
to 40 M© , 0.2% + 1 LSD
Diode test
2.0 V shows diode voltage drop
Display current and % of span
Yes
Auto step, auto ramp
Yes
Environmental Specifications
Operating Temperature
-20 º C to 55 º C
Storage Temperature
-40 º C to 60 º C
Humidity ( Without Condensation)
95% up to 30 º C
75% up to 40 º C
45% up to 50 º C
35% up to 55 º C
Temperature Coefficient
0.05 x ( specified accuracy) per º C ( for temperatures 28 º C)
Safety Specifications
Electrical Safety
Designed in accordance with IEC 1010-1, ANSI/ ISA S82.01-1994 and CAN/ CSA C22.2 No. 1010.1-92
Overvoltage category
IEC 1010-1 CAT III 1000 V
IEC 1010-1 CAT IV 600 V
Maximum voltage
1000 V rms
Mechanical & General Specifications
Size
50 x 100 x 203 mm ( 1.25 " H x 3.41 " W x 7.35 " L)
Weight
610 g ( 1.6 lbs)
Batteries
4 AA Alkaline batteries
Battery Life
140 hours typical ( measurement) , 10 hours typical ( sourcing 20 mA)
Shock & Vibration
Random, 2 g, 5-500 Hz
1 meter drop test
ProcessMeter Fluke 789
Include :
AC72 Alligator Clips
Four AA 1.5 V alkaline battery ( installed)
TL71 Safety-Designed Test lead Set
Users Manual and Quick Reference Guide
Informasi selengkapnya
Hubungi Putra Buana Instrument
T : 02151176451
F : 0217302811
M : 081908101888
CP : Irfan
Tampilkan Lebih Banyak