Detail Fluka 87V True RMS Digital Multimeters Call Irfan 02151176451
True RMS Digital Multimeters Fluka 80 Series ( Fluke 83V, 87V) Call Irfan 02151176451
Feature:
features for maximum productivity
Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment ( 87V)
Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument ( 87V)
Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
Large digit display with bright, two-level backlight makes the 80- Series V significantly easier to read than older models
Electrical safety
All inputs are protected to the 2nd edition of ANSI/ ISA S82.01 and EN61010-1 CAT IV 600V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals
Until now, there hasn' t been a multimeter able to accurately measure adjustable speed drives. But the new Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you' ll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.
Unique function for accurate measurements of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals
Accurately measure the frequency ( motor speed) . Frequency measurement not affected by the ASDs carrier frequency
Measure AC current with an optional current clamp accessory
Compare reading from the 87V with the display on the ASD
Special shielding blocks high frequency, high-energy noise generated by large drive systems
Complex PWM drive signals are not a problem for the Fluke 87V
Pulse-width modulated detail of 50 Hz motor drive output voltage. 1000 V, 50 micro-second pulses can cause erratic behavior in some test equipment
Specifications
Voltage DC
Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ± ( 0.1% + 1)
Fluke 87 V: ± ( 0.05% + 1)
Maximum Resolution: Fluke 83 V: 100 µ V
Fluke 87 V: 10 µ V
Voltage AC
Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ± ( 0.5% + 2)
Fluke 87 V: ± ( 0.7% + 2) True RMS
AC Bandwidth Fluke 83 V: 5kHz
Fluke 87 V: 20kHz*
* with low pass filter; 3db @ 1kHz
Maximum Resolution: 0.1 mV
Current DC
Maximum Amps: 10A ( 20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ± ( 0.4% + 2)
Fluke 87 V: ± ( 0.2% + 2)
Maximum Resolution: Fluke 83 V: 0.01 mA
Fluke 87 V: 0.01 µ A
Current AC
Maximum Amps: 10A ( 20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ± ( 1.2% + 2)
Fluke 87 V: ± ( 1.0% + 2) True RMS
Maximum Resolution: 0.1 µ A
Resistance
Maximum Resistance: 50 M©
Accuracy: Fluke 83 V: ± ( 0.4% + 1)
Fluke 87 V: ± ( 0.2% + 1)
Maximum Resolution: 0.1©
Capacitance
Maximum Capacitance 9, 999 µ F
Accuracy ± ( 1% + 2)
Maximum Resolution 0.01 nF
Frequency
Maximum Frequency 200 kHz
Accuracy ± ( 0.005% + 1)
Maximum Resolution 0.01 Hz
Duty Cycle
Maximum Duty Cycle 99.9%
Accuracy ± ( 0.2% per khz + 0.1% )
Maximum Resolution 0.1%
Temperature Measurement
Fluke 87 V, 87 V/ E: -200.0° C - 1090° C
-328.0° F - 1994.0° F
excluding probe
80 BK Temperature Probe
-40.0° C - 260° C
-40.0° F - 500° F, 2.2° C or 2% whichever is greater
Conductance
Maximum Conductance 60.00 nS
Accuracy ± ( 1.0% + 10)
Maximum Resolution 0.01 nS
Diode
Range: 3 V
Resolution: 1 mV
Accuracy: ± ( 2 % + 1)
Duty Cycle Range
Accuracy: Within ± ( 0.2% per kHz + 0.1 % )
Environmental Specifications
Operating Temperature -20° C to + 55° C
Storage Temperature -40° C to + 60° C
Humidity ( Without Condensation)
0% - 90% ( 0° C - 35° C)
0% - 70% ( 35° C - 55° C)
Operating Altitude 2000 m
Safety Specifications
Overvoltage category
EN 61010-1 to 1000 V CAT III, 600V CAT IV
Agency Approvals
UL, CSA, TÜ V, VDE listed
Mechanical & General Specifications
Size 201 x 98 x 52 mm ( with holster)
Weight 355 g
Weigh With Holster and Flex-Stand 624 g
Display
Digital: 6000 counts updates 4/ sec.
( Model 87 also has 19, 999 counts in high-resolution mode.)
Analog: 32 segments, updates 40/ sec.
Frequency: 19, 999 counts, updates 3/ sec at > 10 Hz.
Battery Life Alkaline: ~ 400 hours typical, without backlight
Shock 1 Meter drop per IEC 61010-1: 2001
Vibration Per MIL-PRF-28800 for a Class 2 instrument
Fluke 83V Multimeter
Includes:
TL75 test leads
AC72 Alligator Clips
Holster
9V battery ( installed)
Getting Started Manual
CD with detailed manual
Fluke 87V Multimeter
Includes:
TL75 test leads
AC72 Alligator Clips
Holster
9V battery ( installed)
Getting Started Manual
CD with detailed manual
80BK temperature probe
Informasi selengkapnya
Hubungi Putra Buana Instrument
T : 02151176451
F : 0217302811
M : 081908101888
CP : Irfan
Tampilkan Lebih Banyak