Back to Top

Hi, Guest!
  • FLUKE
  • Fluke 115 Digital Multimeter Call Irfan 02151176451

Fluke 115 Digital Multimeter Call Irfan 02151176451

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
11 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Fluke 115 Digital Multimeter Call Irfan 02151176451

Fluke 115 Digital Multimeter Call Irfan 02151176451 Digital Multimeter Fluke 115 Large white LED backlight to work in poorly lit areas Resistance and continuity Min/ Max/ Average to record signal fluctuations CAT III 600 V safety rated Safety conformance All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜ V listed and VDE. Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 Display Digital: 6, 000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating Temperature -10 ° C to + 50 ° C Storage Temperature -40 ° C to + 60 ° C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2 DC volts Range/ Resolution: 6.000 V / 0.001 V Range/ Resolution: 60.00 V / 0.01 V Range/ Resolution: 600.00 V / 0.1 V Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2 AC millivolts1 true-rms Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz) AC volts1 true-rms Range/ Resolution: 6.000 V / 0.001 V Range/ Resolution: 60.00 V / 0.01 V Range/ Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz) Continuity Range: 600 & Resolution: 1 & Accuracy: Beeper on 250 & ; detectsopens or shorts of 500 ¼ s or longer. Ohms Range/ Resolution: 600.0 & / 0.1 & Range/ Resolution: 6.000 k& / 0.001 k& Range/ Resolution: 60.00 k& / 0.01 k& Range/ Resolution: 600.0 k& / 0.1 k& Range/ Resolution: 6.000 M& / 0.001 M& Accuracy: 0.9 % + 1 Range/ Resolution: 40.00 M& / 0.01 M& Accuracy: 5 % + 2 Diode Test Range/ Resolution: 2.00 V / 0.001 V Accuracy: 0.9% + 2 Capacitance Range/ Resolution: 1000 nF / 1 nF Range/ Resolution: 10.00 µ F / 0.01 µ F Range/ Resolution: 100.0 µ F / 0.1 µ F Range/ Resolution: 9999 µ F / 1 µ F Range/ Resolution: 100 µ F to 1000 µ F Accuracy: 1.9% + 2 Range/ Resolution: > 1000 µ F Accuracy: 5% + 20% Lo-Z Capacitance Range: 1 nF to 500 µ F Accuracy: 10% + 2 typical AC amps true-rms ( 45 Hz to 500Hz) Range/ Resolution: 6.000 A / 0.001 A Range/ Resolution: 10.00 A / 0.01 A Accuracy: 1.5% + 3 20 A overload for 30-seconds max DC amps Range/ Resolution: 6.000 A / 0.001 A Range/ Resolution: 10.00 A / 0.01 A Accuracy: 1.0% + 3 20 A overload for 30-seconds max Hz ( V or A input) 2 Range/ Resolution: 99.99 Hz / 0.01 Hz Range/ Resolution: 999.9 Hz / 0.01 Hz Range/ Resolution: 9.999 kHz / 0.001 kHz Range/ Resolution: 50 kHz / 0.01 kHz Accuracy: 0.1% + 2 Notes: 1) All ac voltage ranges except Auto-V/ LoZ are specified from 1 % to 100 % of range. Auto-V/ LoZ is specified from 0.0 V. 2) Temperature uncertainty ( accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/ Resolution: -40 ° F to 752 ° F / 0.2 ° F 2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage Mechanical & General Specifications Size 167 x 84 x 46 mm ( 6.57 " x 3.31 " x 1.82 " ) Weight 550 g Model includes the following: Installed 9 V battery Test leads User manual HVAC Multimeter Fluke 116 with Temperature and Microamps Call Irfan 02151176451 Built-in thermometer for HVAC applications Microamps to test flame sensors Low input impedance: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas Resistance, continuity, frequency and capacitance Min/ Max/ Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger ( ToolPak™ ) CAT III 600 V safety rated Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Display Digital: 6, 000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating Temperature -10 ° C to + 50 ° C Storage Temperature -40 ° C to + 60 ° C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2 DC volts Range/ Resolution: 6.000 V / 0.001 V Range/ Resolution: 60.00 V / 0.01 V Range/ Resolution: 600.00 V / 0.1 V Accuracy: ± ( [ % of reading] + [ counts] ) : 0.5% + 2 Auto volts Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0 % + 3 ( dc, 45 Hz to 500 Hz) 4.0 % + 3 ( 500 Hz to 1 kHz) AC millivolts1 true-rms Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz) AC volts1 true-rms Range/ Resolution: 6.000 V / 0.001 V Range/ Resolution: 60.00 V / 0.01 V Range/ Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz) Continuity Range: 600 & Resolution: 1 & Accuracy: Beeper on 250 & ; detects opens or shorts of 500 ¼ s or longer. Ohms Range/ Resolution: 600.0 & / 0.1 & Range/ Resolution: 6.000 k& / 0.001 k& Range/ Resolution: 60.00 k& / 0.01 k& Range/ Resolution: 600.0 k& / 0.1 k& Range/ Resolution: 6.000 M& / 0.001 M& Accuracy: 0.9 % + 1 Range/ Resolution: 40.00 M& / 0.01 M& Accuracy: 1.5 % + 2 Diode Test Range/ Resolution: 2.000 V / 0.001 V Accuracy: 0.9% + 2 Capacitance Range/ Resolution: 1000 nF / 1 nF Range/ Resolution: 10.00 ¼ F / 0.01 ¼ F Range/ Resolution: 100.0 ¼ F / 0.1 ¼ F Range/ Resolution: 9999 ¼ F / 1 ¼ F Range/ Resolution: 100 ¼ F to 1000 ¼ F Accuracy: 1.9% + 2 Range/ Resolution: > 1000 ¼ F Accuracy: 5% + 20% LoZ capacitance Range: 1 nF to 500 ¼ F Accuracy: 10% + 2 typical Temperature2 ( Type-K thermocouple) Range/ Resolution: -40 ° C to 400 ° C / 0.1 ° C Accuracy: 1% + 102 Range/ Resolution: -40 ° F to 752 ° F / 0.2 ° F Accuracy: 1% + 182 AC ¼ amps true-rms ( 45 Hz to 500 Hz) Range/ Resolution: 600.0 ¼ A / 0.1 ¼ A Accuracy: 1.0% + 2 DC ¼ amps Range/ Resolution: 600.0 ¼ A / 0.1 ¼ A Accuracy: 1.0% + 2 Hz ( V or A input) 2 Range/ Resolution: 99.99 Hz / 0.01 Hz Range/ Resolution: 999.99 Hz / 0.1 Hz Range/ Resolution: 9.999 Hz / 0.001 Hz Range/ Resolution: 50.00 Hz / 0.01 Hz Accuracy: 0.1% + 2 Notes: 1) All ac voltage ranges except Auto-V/ LoZ are specified from 1 % to 100 % of range. Auto-V/ LoZ is specified from 0.0 V. 2) Temperature uncertainty ( accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/ Resolution: -40 ° F to 752 ° F / 0.2 ° F Mechanical & General Specifications Size 167 x 84 x 46 mm ( 6.57 " x 3.31 " x 1.82 " ) Weight 550 g HVAC Multimeter Model includes the following: 4 mm silicone test lead set 80BK Integrated Temperature probe Holster Installed 9 V battery User manual Informasi selengkapnya Hubungi Putra Buana Instrument T : 02151176451 F : 0217302811 M : 081908101888 CP : Irfan
Tampilkan Lebih Banyak