Back to Top

Hi, Guest!
  • FLUKE
  • Fluke 117, Digital Multimeter with Non-Contact voltage Call Irfan 02151176451

Fluke 117, Digital Multimeter with Non-Contact voltage Call Irfan 02151176451

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
3 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Fluke 117, Digital Multimeter With Non-Contact Voltage Call Irfan 02151176451

Fluke 117, Digital Multimeter with Non-Contact voltage Call Irfan 02151176451 Feature : VoltAlert™ technology for non-contact voltage detection AutoVolt automatic ac/ dc voltage selection Low input impedance: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas True-rms for accurate measurements on non-linear loads Measures 10 A ( 20 A overload for 30-seconds) Resistance, continuity, frequency and capacitance Min/ Max/ Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger ( ToolPak™ ) for hands free operation CAT III 600 V safety rated Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Fuse for A input 11 A, 1000 V FAST Fuse ( Fluke PN 803293) Display Digital : 6, 000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating Temperature -10 ° C to + 50 ° C Storage Temperature -40 ° C to + 60 ° C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range : 600.0 mV Resolution : 0.1 mV Accuracy : ± ( [ % of reading] + [ counts] ) : 0.5% + 2 DC volts Range/ Resolution: 6.000 V / 0.001 V Range/ Resolution: 60.00 V / 0.01 V Range/ Resolution: 600.00 V / 0.1 V Accuracy : ± ( [ % of reading] + [ counts] ) : 0.5% + 2 Auto volts Range : 600.0 V Resolution : 0.1 V Accuracy : 2.0 % + 3 ( dc, 45 Hz to 500 Hz) 4.0 % + 3 ( 500 Hz to 1 kHz) AC millivolts1 true-rms Range : 600.0 mV Resolution : 0.1 mV Accuracy : 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz) AC volts1 true-rms Range/ Resolution: 6.000 V / 0.001 V Range/ Resolution: 60.00 V / 0.01 V Range/ Resolution: 600.0 V / 0.1 V Accuracy : 1.0 % + 3 ( dc, 45 Hz to 500 Hz) 2.0 % + 3 ( 500 Hz to 1 kHz) Continuity Range : 600 & Resolution : 1 & Accuracy: Beeper on 250 & ; detects opens or shorts of 500 ¼ s or longer. Ohms Range/ Resolution: 600.0 & / 0.1 & Range/ Resolution: 6.000 k& / 0.001 k& Range/ Resolution: 60.00 k& / 0.01 k& Range/ Resolution: 600.0 k& / 0.1 k& Range/ Resolution: 6.000 M& / 0.001 M& Accuracy : 0.9 % + 1 Range/ Resolution: 40.00 M& / 0.01 M& Accuracy : 5 % + 2 Diode Test Range/ Resolution: 2.000 V / 0.001 V Accuracy : 0.9% + 2 Capacitance Range/ Resolution: 1000 nF / 1 nF Range/ Resolution: 10.00 ¼ F / 0.01 ¼ F Range/ Resolution: 100.0 ¼ F / 0.1 ¼ F Range/ Resolution: 9999 ¼ F / 1 ¼ F Range/ Resolution: 100 ¼ F to 1000 ¼ F Accuracy : 1.9% + 2 Range/ Resolution: > 1000 ¼ F Accuracy : 5% + 20% LoZ capacitance Range : 1 nF to 500 ¼ F Accuracy : 10% + 2 typical AC amps true-rms ( 45 Hz to 500 Hz) Range/ Resolution: 6.000 A / 0.001 A Range/ Resolution: 10.00 A / 0.01 A Accuracy : 1.5% + 3 20 A continuous overload for 30 seconds max DC amps Range/ Resolution: 6.000 A / 0.001 A Range/ Resolution: 10.00 A / 0.01 A Accuracy : 1.0% + 3 20 A continuous overload for 30 seconds max Hz ( V or A input) 2 Range/ Resolution: 99.99 Hz / 0.01 Hz Range/ Resolution: 999.99 Hz / 0.1 Hz Range/ Resolution: 9.999 Hz / 0.001 Hz Range/ Resolution: 50.00 Hz / 0.01 Hz Accuracy : 0.1% + 2 Notes: 1) All ac voltage ranges except Auto-V/ LoZ are specified from 1 % to 100 % of range. Auto-V/ LoZ is specified from 0.0 V. 2) Temperature uncertainty ( accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/ Resolution: -40 ° F to 752 ° F / 0.2 ° F Mechanical & General Specifications Size 167 x 84 x 46 mm ( 6.57 " x 3.31 " x 1.82 " ) Weight 550 g Model includes the following: 4 mm silicone test lead set Holster User manual Informasi selengkapnya Hubungi Putra Buana Instrument T : 02151176451 F : 0217302811 M : 081908101888 CP : Irfan
Tampilkan Lebih Banyak